Our Recent Completions: Basement Waterproofing on Dealtry Road, Putney SW15

After: completed Type C basement waterproofing in a Putney cellar

We have just completed a Type C cavity drain waterproofing system in the cellar of a Victorian house on Dealtry Road in Putney, SW15. The aim was simple: turn a damp, unusable cellar into a dry space ready for the next stage of the renovation.

Project at a glance

LocationDealtry Road, Putney, London SW15
PropertyVictorian house – existing cellar
Project typeBasement / cellar waterproofing (refurbishment)
SystemType C cavity drain system to BS 8102:2022
Products usedPermaSEAL® by Permagard – membranes, plugs, drainage channel and sump
Duration1 week
Completed2026
Guarantee10 years

The brief

The client asked us to waterproof the cellar so it could become a dry, usable space as part of a wider renovation of the house. They needed a long-term solution that would cope with the old stone and brick walls, could be finished over by the main contractor, and was installed quickly so the rest of the programme was not held up. We completed the waterproofing in one week.

Before: the starting point

Like many London cellars, this one had old mixed stone-and-brick walls with soft, sandy mortar, later blockwork piers and an old concrete floor slab. The walls and the wall-to-floor joint showed clear signs of damp and water staining – the usual story for rooms below ground level, where groundwater presses against the walls all year round.

What we did

  1. Survey and design to BS 8102:2022. We chose a Type C (drained) system. It does not try to hold water back – it lets it drain away safely behind a membrane, so it works on old walls that could never be sealed.
  2. Perimeter drainage channel. The slab was cut back around the walls and piers and a drainage channel was laid, so any water reaching the base of the walls is collected and led to the sump.
  3. Studded wall membrane. A PermaSEAL cavity drain membrane was fixed to all walls with sealed plugs, with corners, piers and returns carefully detailed and taped.
  4. Service entries sealed. Pipes and cables passing through the walls were sealed into the membrane, so there are no weak points.
  5. Floor membrane. PermaSEAL studded floor membrane was laid over the slab and all joints were taped, ready for insulation and screed.

Products used: the whole system – wall and floor membranes, fixing plugs, drainage channel and sump – is the PermaSEAL® cavity drain system from Permagard, a UK supplier of basement waterproofing products designed for Type C protection to BS 8102:2022. Using one manufacturer’s complete system means every part is designed to work together.

Drainage channel installed at the base of the cellar wall, Dealtry Road Putney
Drainage channel laid at the base of the wall

After: a dry, protected cellar

The cellar is now fully lined. Any water that comes through the old walls runs down behind the membrane, into the channel and away to the sump – it never reaches the inside of the room. The space is ready for the main contractor to finish, and the system is covered by our 10-year basement waterproofing guarantee.

Damp cellar or basement in London?

We survey, design and install basement waterproofing to BS 8102 across London. Start with a damp survey – the fee is deducted from the cost of the works if you go ahead – or read more about our basement waterproofing. Call us on 020 3432 4842 or send us a message.

Book Your Survey

Are you a: